Appointed retail & small lot distributors
Heatflo Sealants

Fortafix High Temperature Fixative - Ropefix

Fortafix RopeFix is a clear, water based liquid that can be used on its own as a glassy transparent adhesive for light film applications for bonding, assembling, jointing or repairing glass and ceramics etc. Used extensively in the Heating and Ventilation Industry to attach mineral fibre, rope, tape etc. to metal and glass and most inorganic materials as well as being useful for after sales installations and service problems. With a maximum continuous working temperature is approx. 800°C. (Softening Point)

Typically Used For

·  High temperature rope fixative
·  Fixing, Bonding, Assembling, Repairing - glass items & ceramics etc.

Suitable For

·  Thin films/Coating - Yes
·  Bonding - Yes
·  Encapsulation - No
·  Thick Sections - No

Property

Value

Major Constituent

Alkali Silicate Glass Solution

Ready Mixed or 2 part

Ready Mixed

Dispensable

Yes

Relative Viscosity

50 - 70 cP @ 20°C Spindle 3 Speed 10 (Brookfield)

Coverage Rate/Coating Thickness

 

Softening Temperature (°C):

700°C

Melting Temperature (°C):

800°C

Wet Density (g.cm-3):

1.45

Colour:

Clear Liquid

Compressive Strength:

 

Thermal Conductivity (W.m-1.K-1):

 

Thermal Expansion (x10-6C-1):

 

Dielectric Strength (KV.mm-1) @ RT:

 

Volume Resistivity (Ωcm) @ RT:

 

pH:

13

Expansion on Setting %:

0

Shrinkage (Linear %): 150-500°C

 

Shrinkage (Volume %): 150-500°C

 

Hardness Moh’s Scale

 

Oxidation Resistance

Excellent

Alkali Resistance

Can be re-dissolved at high pH & temperature

Acid Resistance

Excellent - except hydrofluoric

Cure Guide

Water based product - requires heat curing.

Shelf Life:

12 Months

Packaging:

125 ml, 250ml, 1 litre, 5 litre, 25 litre

Additional Information

Solids by weight: 42%

Application

IT IS ESSENTIAL THAT ALL SURFACES TO BE BONDED ARE FREE FROM OIL, DUST OR ANY FORM OF SURFACE COATING OR CONTAMINATION.
·  Stir contents of the container prior to use, to overcome the effects of any settlement of the ingredients during storage.
·  Ensure that all surfaces to be bonded sealed or insulated, are degreased, clean and free from contamination.
·  A light surface abrasion of the material to be bonded will increase the amount of surface area available for adhesion and will give improved mechanical key.
·  Apply the adhesive to all surfaces to be bonded.
·  Join and apply moderate pressure to ensure even anchorage and solid contact of the surfaces to be bonded, ensure that all surface are fully wetted by the adhesive.
·  Secure the components and allow the adhesive to set and harden.

Curing

This product is water based. In order to cure of the material it is necessary to fully dry & dehydrate the adhesive, by heating as gently & progressively as time and circumstances will allow. The ease by which full curing can be achieved is dependant on the porosity of the substrate, as well as the amount of available surface through which the adhesive film can dry.
The cement should be allowed to harden at a minimum air temperature of 20°C until initial set has taken place. After this period the hardening process may be accelerated using the following typical schedule;
·  Heat from 20° to 80°C @ 4°C per minute (15 minutes). Hold for 10-20 minutes
·  Heat from 80° to 140°C @ 2°C per minute (30 minutes). Hold for 120-180 minutes
·  Heat from 140° to 200°C @ 0.2°C per minute (300 minutes).
·  Above 200°C - raise temperature @ 1°C per minute to required temperature, allow to cool progressively.
Hardening and curing times given are approximate in view of possible variations in adhesive volume, glue line thickness, and substrate conditions, all of which will influence curing times.

 

3